Fourth, confirm whether the installation is a new construction job using a PS900 series supply or a service job on an existing PS873 installation. If the existing PS873 cabinet is being reused, the PS914-RFK retrofit kit allows the main board to be updated without replacing the enclosure. If the option boards are also being replaced, confirm that PS900 series boards are used, since PS873 option boards are not compatible with PS900 series main boards.
Where the Power Supply Is Installed Von Duprin power supplies are wall-mounted or ceiling-mounted units installed near the door or in an accessible mechanical space. They are not visible from the door side during normal operation. Common installation locations include above a suspended ceiling tile near the door, in a nearby electrical or mechanical room, or in a dedicated enclosure on the wall adjacent to the opening. The power supply must be accessible for service, battery backup board installation if that option is included, and LED status monitoring. Running the wiring from the power supply to the exit device requires a low-voltage wire path through the door frame, typically through a transfer hinge or a power transfer device, depending on the door configuration.
The Relationship Between the Power Supply and the Access Control System The Von Duprin power supply is not an access control panel. It is a power conversion and distribution device with relay outputs that interface with an access control system. The access control system, which includes the card reader, keypad, or credential device, makes the decision about whether access is authorized. When access is granted, the access control panel sends a signal to the relay on the Von Duprin power supply, which then momentarily energizes or de-energizes the electrified latch retraction device to allow the door to open. This two-component arrangement means the power supply and the access control panel are separate purchases with separate installation scopes. The power supply handles power conversion and device activation. The access control panel handles credential management, audit trails, and access logic. For an overview of how electrified panic devices fit into the larger exit hardware category, the American Locksets rim exit devices guide provides helpful context on where these components are used in commercial buildings.
Frequently Asked Questions